A retrospective analysis comparing functional and radiological outcomes after treatment of unstable distal radius fractures using volar locked plate versus percutaneous fixation

Authors

  • Ashish Pande Department of Orthopedics, Military Hospital Kirkee, Kirkee, Pune, Maharashtra, India
  • Girish G. Mugdum Department of Orthopedics, Military Hospital Kirkee, Kirkee, Pune, Maharashtra, India
  • Anil K. Mishra Department of Orthopedics, Military Hospital Kirkee, Kirkee, Pune, Maharashtra, India

DOI:

https://doi.org/10.18203/issn.2455-4510.IntJResOrthop20193836

Keywords:

Distal radius, Volar locking plate, External fixation

Abstract

Background: Distal radius fractures are one of the most routinely encountered injuries in an orthopaedic setting. Despite the wide variety of treatment options available there is still debate about the optimal way to treat these fractures. The aim was to evaluate and compare functional and radiological outcomes of unstable distal radius fractures treated by either by using volar locking compression plating (VLP) or by using percutaneous fixation augmented by Kirschner (K) wires (EF).

Methods: A retrospective analysis was carried out on all cases of acute unstable unilateral fracture distal radius who were admitted between January 2015 and December 2017 and were treated either by VLP or EF. QuickDASH score and PRWE were documented at every follow up in OPD at 6 weeks, 6 months and 1 year post-op along with serial X-rays at immediate post-op and 01 year which were then compared.

Results: A total of 122 cases of fracture distal radius were selected for study which fulfilled the inclusion criteria out of which 49 were treated by VLP and 73 by EF. There was no statistical difference in QuickDASH, PRWE scores or wrist ROM between two groups at1 year follow up. However VLP group was better in maintaining palmar tilt, radial length and inclination at the end of 1 year.

Conclusions: Both VLP and EF show comparable and predictable good outcomes in treating unstable distal radius fractures when measured in terms of ROM and clinically validated patient outcome scores at 01 year follow up with similar rate of complications.

 

Author Biography

Ashish Pande, Department of Orthopedics, Military Hospital Kirkee, Kirkee, Pune, Maharashtra, India

Assistant Professor

Dept of Orthopedics

References

Court-Brown CM, Caesar B. Epidemiology of adult fractures: A review. Injury. 2006;37(8):691-7.

MacIntyre NJ, Dewan N. Epidemiology of distal radius fractures and factors predicting risk and prognosis. J Hand Ther. 2016;29(2):136-45.

McQueen M, Caspers J. Colles fracture: does the anatomical result affect the final function? J Bone Joint Surg Br. 1988;70(4):649-51.

Orbay JL. The treatment of unstable distal radius fractures with volar fixation. Hand Surg. 2000;5(2):103-12.

Wilcke MK, Hammarberg H, Adolphson PY. Epidemiology and changed surgical treatment methods for fractures of the distal radius: a registry analysis of 42,583 patients in Stockholm County, Sweden, 2004-2010. Acta Orthop. 2013;84(3):292-6.

Fanuele J, Koval KJ, Lurie J, Zhou W, Tosteson A, Ring D. Distal radial fracture treatment: what you get may depend on your age and address. J Bone Joint Surg Am. 2009;91(6):1313-9.

Karantana A, Downing ND, Forward DP, Hatton M, Taylor AM, Scammell BE, et al. Surgical treatment of distal radial fractures with a volar locking plate versus conventional percutaneous methods: a randomized controlled trial. J Bone Joint Surg Am. 2013;95(19):1737-44.

Lozano-Calderon SA, Souer S, Mudgal C, Jupiter JB, Ring D. Wrist mobilization following volar plate fixation of fractures of the distal part of the radius. J Bone Joint Surg Am. 2008;90(6):1297-304.

Alter TH, Ilyas AM. Complications Associated with Volar Locking Plate Fixation of Distal Radial Fractures. JBJS Rev. 2018;6(10):7.

Bentohami A, de Burlet K, de Korte N, van den Bekerom MP, Goslings JC, Schep NW. Complications following volar locking plate fixation for distal radial fractures: a systematic review. J Hand Surg Eur Vol. 2014;39(7):745-54.

Egol K, Walsh M, Tejwani N, McLaurin T, Wynn C, Paksima N. Bridging external fixation and supplementary Kirschner-wire fixation versus volar locked plating for unstable fractures of the distal radius: a randomised, prospective trial. J Bone Joint Surg Br. 2008;90(9):1214-21.

Rozental TD, Blazar PE, Franko OI, Chacko AT, Earp BE, Day CS. Functional outcomes for unstable distal radial fractures treated with open reduction and internal fixation or closed reduction and percutaneous fixation. A prospective randomized trial. J Bone Joint Surg Am. 2009;91(8):1837-46.

Kleinlugtenbelt YV, Krol RG, Bhandari M, Goslings JC, Poolman RW, Scholtes VAB. Are the patient-rated wrist evaluation (PRWE) and the disabilities of the arm, shoulder and hand (DASH) questionnaire used in distal radial fractures truly valid and reliable? Bone Joint Res. 2018;7(1):36-45.

Paranaiba VF, Santos J, Raduan Neto J, Moraes VY, Belotti JC, Faloppa F. PRWE application in distal radius fracture: comparison and correlation with established outcomes. Rev Bras Ortop. 2017;52(3):278-83.

Hammer OL, Clementsen S, Hast J, Saltyte Benth J, Madsen JE, Randsborg PH. Volar Locking Plates Versus Augmented External Fixation of Intra-Articular Distal Radial Fractures: Functional Results from a Randomized Controlled Trial. J Bone Joint Surg Am. 2019;101(4):311-21.

Lichtman DM, Bindra RR, Boyer MI, Putnam MD, Ring D, Slutsky DJ, et al. American Academy of Orthopaedic Surgeons clinical practice guideline on: the treatment of distal radius fractures. J Bone Joint Surg Am. 2011;93(8):775-8.

Leung F, Tu YK, Chew WY, Chow SP. Comparison of external and percutaneous pin fixation with plate fixation for intra-articular distal radial fractures. A randomized study. J Bone Joint Surg Am. 2008;90(1):16-22.

Rizzo M, Katt BA, Carothers JT. Comparison of locked volar plating versus pinning and external fixation in the treatment of unstable intraarticular distal radius fractures. Hand (NY). 2008;3(2):111-7.

Green DP. Pins and plaster treatment of comminuted fractures of the distal end of the radius. J Bone Joint Surg Am. 1975;57(3):304-10.

Atroshi I, Brogren E, Larsson GU, Kloow J, Hofer M, Berggren AM. Wrist-bridging versus non-bridging external fixation for displaced distal radius fractures: a randomized assessor-blind clinical trial of 38 patients followed for 1 year. Acta Orthop. 2006;77(3):445-53.

McQueen M. Management of distal radial fractures. J R Coll Surg Edinb. 1989;34(3):161.

Chen NC, Jupiter JB. Management of distal radial fractures. J Bone Joint Surg Am. 2007;89(9):2051-62.

Bacorn RW, Kurtzke JF. Colles' fracture; a study of two thousand cases from the New York State Workmen's Compensation Board. J Bone Joint Surg Am. 1953;35(3):643-58.

McQueen MM. Redisplaced unstable fractures of the distal radius. A randomised, prospective study of bridging versus non-bridging external fixation. J Bone Joint Surg Br. 1998;80(4):665-9.

Wright TW, Horodyski M, Smith DW. Functional outcome of unstable distal radius fractures: ORIF with a volar fixed-angle tine plate versus external fixation. J Hand Surg Am. 2005;30(2):289-99.

Oshige T, Sakai A, Zenke Y, Moritani S, Nakamura T. A comparative study of clinical and radiological outcomes of dorsally angulated, unstable distal radius fractures in elderly patients: intrafocal pinning versus volar locking plating. J Hand Surg Am. 2007;32(9):1385-92.

Rein S, Schikore H, Schneiders W, Amlang M, Zwipp H. Results of dorsal or volar plate fixation of AO type C3 distal radius fractures: a retrospective study. J Hand Surg Am. 2007;32(7):954-61.

Klug RA, Press CM, Gonzalez MH. Rupture of the flexor pollicis longus tendon after volar fixed-angle plating of a distal radius fracture: a case report. J Hand Surg Am. 2007;32(7):984-8.

Arora R, Lutz M, Hennerbichler A, Krappinger D, Espen D, Gabl M. Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate. J Orthop Trauma. 2007;21(5):316-22.

Rampoldi M, Marsico S. Complications of volar plating of distal radius fractures. Acta Orthop Belg. 2007;73(6):714-9.

Marcheix PS, Dotzis A, Benko PE, Siegler J, Arnaud JP, Charissoux JL. Extension fractures of the distal radius in patients older than 50: a prospective randomized study comparing fixation using mixed pins or a palmar fixed-angle plate. J Hand Surg Eur Vol. 2010;35(8):646-51.

MacDermid JC, Roth JH, Richards RS. Pain and disability reported in the year following a distal radius fracture: a cohort study. BMC Musculoskelet Disord. 2003;4:24.

MacDermid JC, Richards RS, Roth JH. Distal radius fracture: a prospective outcome study of 275 patients. J Hand Ther. 2001;14(2):154-69.

Seki Y, Aoki T, Maehara H, Shirasawa S. Distal locking screw length for volar locking plate fixation of distal radius fractures: Postoperative stability of full-length unicortical versus shorter screws. Hand Surg Rehabil. 2019;38(1):28-33.

Park DH, Goldie BS. Volar plating for distal radius fractures--do not trust the image intensifier when judging distal subchondral screw length. Techniques Hand Upper Extremity Surg. 2012;16(3):169-72.

Shyamalan G, Theokli C, Pearse Y, Tennent D. Volar locking plates versus Kirschner wires for distal radial fractures--a cost analysis study. Injury. 2009;40(12):1279-81.

Downloads

Published

2019-08-26

Issue

Section

Original Research Articles